AC asynchronous motors are widely used in various fields of the national economy. The direct starting of asynchronous motors has the problems of small starting torque, large starting current, large impact on the power grid, difficulty in starting, large impact on mechanical equipment, short service life of the motor, large maintenance workload, and high maintenance costs.

KSSHV voltage soft starting can reduce the power grid voltage drop caused by the direct start of the motor. The use of this product does not affect the normal operation of other equipment in the common network,and can reduce the impulse current of the motor, which will cause the local temperature rise of the motor to be too large and reduce the life of the motor. It can reduce the mechanical impact caused by direct starting and accelerate the wear of the transmission machinery. Reduce electromagnetic interference, the impact current will interfere with the normal operation of the electrical instrument in the form of electromagnetic waves, high voltage soft start can start and stop freely, improve work efficiency.

High voltage soft start devices include KSSHV-6 standard 6kV solid state soft start device, KSSHV-10 standard 10kV solid state soft start device and KSSHV-E series all-in-one high voltage solid state soft start device.

KSSHV high voltage soft start is suitable for starting AC motors with rated voltage 6-10KV. Products are widely used in large-scale iron and steel, petroleum, chemical, aluminum, fire, mining, sewage treatment,electric power and other industrial fields, can be well used with motor drive equipment. Such as: pumps,fans, compressors, shredders, mixers, belt machines and other mechanical and electrical equipment.

Features

  • *The switch cabinet, soft starting cabinet, bypass cabinet three-in-one integrated design, small size, easy to install;
  • *Standard configuration includes vacuum circuit breaker and bypass vacuum contactor, no need to prepare operating cabinet or switch cabinet, high design costs will never return;
  • *Small size, the volume of the same power is 50% to 60% of other methods of soft starting, easy installation,space saving;
  • *The cabinet is made of imported negative aluminum zinc plate, processed by CNC machine tool,
  • completely metal armored, assembled structure, wide combination scheme, advanced multiple flanging process, with rivet nut bolt connection, and high precision, corrosion resistance, light weight, high strength,and strong parts versatility;
  • *Can be equipped with domestic ZN63A-12(VSI) series or imported VD4 series vacuum circuit breaker,wide applicability, high reliability, to achieve maintenance free;
  • *All kinds of handcarts change according to modular building blocks, to ensure that the same specifications of the car can be freely interchangeable, different specifications can not enter;
  • *Highly reliable interlocking device, fully meet the “five prevention” requirements;
  • *Suitable for installation anywhere, with no distance requirement from other equipment layout;
  • *Pressure relief channels are provided in each high pressure chamber to ensure personal safety;
  • *The circuit breaker room and cable room can be equipped with heaters respectively to prevent
  • condensation and corrosion;
  • *The face door is equipped with an observation window to observe the working state of indoor components;
  • *Protection level :IP40

Executive standards

  • GB4208-2008 “Shell Protection Level (Ip Code)”;
  • GB/T3 8 5 9 . 2 – 1 9 9 3 “Se m i c o n d u c t o r Converter Application Guidelines”;
  • IEC 60470 High Voltage AC Contactors;
  • GB/T13422-1992 “Electrical Test method for Semiconductor Power converters”;
  • IEC 61000 Electromagnetic Compatibility;
  • GB/ T3859.1-1993 “Basic Requirements for Semiconductor converters”;
  • GB/T 12173-2008 “Mining general Electrical Equipment”;
  • JB/Z102 “Technical Conditions for High Voltage Electrical appliances used in high altitude areas”;
  • GB 1207-2006 “Electromagnetic Voltage Trans former;
  • JB/T 10251-2001 “AC Motor Power Electronic Soft Starting Device”;
  • IEC 60298 “AC metal enclosed Switchgear and Control Equipment above 1KV and below 52KV”;
  • GB/T 11022-1999 “High voltage switchgear and control equipment standard sharing technical requirements”.

Technical Details

Item Basic parameter
Type of load Three-phase high voltage squirrel cage induction motor, synchronous motor
Alternating current voltage 6- 10KVAC
Operating frequency 50HZ/60Hz±2Hz
Phase sequence KSSHV allows operation in any phase sequence (configurable by parameter)
Bypass contactor Contactor with direct starting capacity
Control power supply AC220V±15%
Instantaneous overvoltage protection dv/dt absorption network
Starting frequency 1-6 times (per hour)
Environmental condition Ambient temperature: -20。C to +50。C
Relative humidity: 5%—95% no condensation
Altitude is less than 1500 meters (more than 1500 meters need to drop capacity)
Operating interface
Language Chinese and English
Data recording
Fault record Record the latest 100 faults
Protection function
Phase loss protection Disconnect any phase of the main power supply during startup or operation
Run overcurrent protection Overcurrent protection setting: 100 ~ 500%le
Phase current unbalance protection Phase current imbalance protection: 20- 100%
Overload protection Overload protection levels: 10A, 10, 20, 30
Underload protection Underload protection level: 50 to 100%
Underload protection operation time: 0- 10S
Starting timeout Overvoltage protection when the main supply voltage is higher than 120% of the rated value
Overvoltage protection Undervoltage protection when the main supply voltage is less than 70% of the rated value
Phase sequence protection Allows operation in any phase sequence (can be set by parameters)
Ground protection Protection when the ground current is greater than the set value
        Communication specification
Communication protocol/interface Modbus RTU
Network connection Each KSSHV can communicate with 32 KSSHV devices
Feature Through the communication interface can observe the running state, programming
  Instrument display
Main supply voltage Displays the three-phase main power supply voltage
Three-phase current Displays three-phase main circuit current

Basic Wiring Diagram

Model & Dimension

Model Rated Voltage Rated Power Rated Current Dimensions W*H*D(mm)
(KV) (kW) (A) G  Conventional Model E Integrated Model
Input: Three Phase 6KV        Output: 6KV   Three Phase
KSSHV-6T-420G 6kV 420 50 1000*2300*1500 1000*2300*1500
KSSHV-6T-630G 6kV 630 75 1000*2300*1500 1000*2300+1500
KSSHV-6T-800G 6kV 800 96 1000*2300*1500 1000*2300*1500
KSSHV-6T-1000G 6kV 1000 120 1000*2300*1500 1000*2300*1500
KSSHV-6T-1250G 6kV 1250 150 1000*2300*1500 1000*2300*1500
KSSHV-6T-1600G 6kV 1600 200 1000*2300*1500 1000*2300*1500
KSSHV-6T-1800G 6kV 1800 218 1000*2300*1500 1000*2300*1500
KSSHV-6T-2250G 6kV 2250 270 1000*2300*1500 1000*2300*1500
KSSHV-6T-2500G 6kV 2500 300 1000*2300+1500 1000*2300*1500
KSSHV-6T-3300G 6kV 3300 400 1000*2300*1500 1000*2300*1500
KSSHV-6T-4150G 6kV 4150 500 Tailor Model Tailor Model
KSSHV-6T-5000G 6kV 5000 600 Tailor Model Tailor Model
Input: Three Phase 10KV        Output: 10KV   Three Phase
KSSHV-10T-420G 10kV 420 30 1000*2300*1500 1000*2300*1500
KSSHV-10T-630G 10kV 630 45 1000*2300*1500 1000*2300*1500
KSSHV-10T-800G 10kV 800 60 1000*2300*1500 1000*2300*1500
KSSHV-10T- 1000G 10kV 1000 73 1000*2300*1500 1000*2300+1500
KSSHV-10T-1250G 10kV 1250 90 1000*2300*1500 1000*2300*1500
KSSHV-10T- 1600G 10kV 1600 115 1000*2300*1500 1000*2300*1500
KSSHV-10T1800G 10kV 1800 130 1000*2300*1500 1000*2300*1500
KSSHV-10T-2250G 10kV 2250 160 1000*2300*1500 1000*2300*1500
KSSHV-10T-2500G 10kV 2500 180 1000*2300*1500 1000*2300*1500
KSSHV-10T2800G 10kV 2800 200 1000*2300*1500 Tailor Model
KSSHV-10T-3300G 10kV 3300 235 1000*2300*1500 Tailor Model
KSSHV-10T-3500G 10kV 3500 250 1000*2300*1500 Tailor Model
KSSHV-10T-4000G 10kV 4000 280 1000*2300*1500 Tailor Model
KSSHV-10T-4500G 10kV 4500 320 1000*2300*1500 Tailor Model
KSSHV-10T-5500G 10kV 5500 400 1000*2300*1500 Tailor Model
KSSHV-10T-6000G 10kV 6000 430 1000*2300*1500 Tailor Model
KSSHV-10T-7000G 10kV 7000 500 1000*2300*1500 Tailor Model
KSSHV-10T-8500G 10kV 8500 600 1000*2300*1500 Tailor Model
KSSHV-10T-10000G 10kV 10000 720 Tailor Model Tailor Model
KSSHV-10T-15000G 10kV 15000 1080 Tailor Model Tailor Model

Case Study

OBTAIN SAMPLES

Effective, safe and reliable. Our equipment guarantees the right solution for any requirement. Benefit from our industry
expertise and generate added value – every day.

Click For Inquiry


  • Previous:
  • Next:

  • Write your message here and send it to us

    Professional technical engineer dedicated to guide you

    According to your actual needs, choose the most reasonable overall design and planning procedures