of Chinese Stone Machinery
Class II |
Type A2 |
Type B2 |
|
Biotechnology |
Medium Preparation |
○ |
○ |
Tissue Culture |
○ |
○ |
|
Blood Elements Analysis |
○ |
○ |
|
Human Histology |
○ |
○ |
|
Polymerase Chain Reaction |
○ |
○ |
|
Microbiology |
Medium Preparation |
○ |
○ |
Culture nuisance odors |
- |
○ |
|
Isolated Clinical Sample |
○ |
○ |
|
Blood Test/Analysis |
○ |
○ |
|
QA/QC |
○ |
○ |
|
Minute Quantities of Volatile Toxic Chemicals |
- |
○ |
|
Trace Amount of Radionucleotides |
- |
○ |
|
Pharmaceutical |
Antitumor drug preparation |
- |
○ |
Trace Amount of Radionucleotides |
- |
○ |
|
Routine research |
Cell/Tissue Immobilization & Staining |
- |
○ |
Toxic Powder/ Suspended Substance |
○ |
○ |
German made ebm-papst motors selected for energy efficiency, compact design, and flat profile.
Sychronously communicates with microprocessor, there is no need for manual speed control Automatically compensates for normal power line variation, air disruption and filter loading.
Motor consumes less energy, reduces heat output and operates more quietly.
ULPA Filtration System
HFsafe LC biosafety cabinets are equipped with long life ULPA filtration technology by Swedish Camfil Farr.
Supply and exhaust filters provide 99.999% typical efficiency for particle size of 0.1 to 0.2 microns, providing superior product protection over conventional HEPA filters.
Silicate glass fiber treated with moisture-proof hydrophobic bonding agent is folded in aluminum alloy frame to enlarge filtration area.
Leak-free performance is guaranteed through structural stability and scan test conducted prior to shipping.
Self-compensation for the clogging of filters optimizes filter use and minimizes service.
Filter Life Indication
Filters has estimated service life, which is uncertain subject to different local air quality, research subjects and operation frequency.
There is potential pollution harzard if operator is unconscious to filter expiration Patented filter life indicator is designed to measure filter life according to actual condition of membrane.
You can rely on filter life indicator to make a confident plan for future filter replacement.
General Specifications, HFsafe LC Biological Safety Cabinets (Class II Type A2) |
||||
Model |
HFsafe-900LC |
HFsafe-1200LC |
HFsafe-1500LC |
HFsafe-1800LC |
Nominal Size |
0.9 meters(3′) |
1.2 meters(4′) |
1.5 meters(5′) |
1.8 meters(6′) |
External Dimensions with Base Stand (W×D×H) |
1040×790×2130mm 40.9”×31.1”×83.9” |
1340×790×2130mm 52.8”×31.1”×83.9” |
1640×790×2130mm 64.6”×31.1”×83.9” |
1940×790×2130mm 76.4”×31.1”×83.9” |
Internal Work Area, Dimensions(W×D×H) |
950×575×625mm 37.4”×22.6”×24.6” |
1250×575×625mm 49.2”×22.6”×24.6” |
1550×575×625mm 61.0”×22.6”×24.6” |
1850×575×625mm 72.8”×22.6”×24.6” |
Internal Work Area,Space |
0.54m2 (5.8 sq.ft) |
0.72m2 (7.8 sq.ft) |
0.9m2 (9.7 sq.ft) |
1.08m2 (11.6 sq.ft) |
Average Airflow Velocity * |
||||
Inflow |
0.53m/s(104.3fpm) |
|||
Downflow |
0.35m/s(68.9fpm) |
|||
Airflow Volume |
||||
Inflow |
363m³/h(213cfm) |
477m³/h(281cfm) |
592m³/h(348cfm) |
706m³/h(416cfm) |
Downflow |
658m³/h(377cfm) |
866m³/h(510cfm) |
1075m³/h(633cfm) |
1282m³/h(755cfm) |
Exhaust |
363m³/h(213cfm) |
477m³/h(281cfm) |
592m³/h(348cfm) |
706m³/h(416cfm) |
ULPA Filter Typical Efficiency |
|
|
|
|
Downflow |
Filters provide 99.9995% typical efficiency for particle size of 0.1 to 0.2 microns |
|||
Exhaust |
Filters provide 99.9995% typical efficiency for particle size of 0.1 to 0.2 microns |
|||
Biosafety Protection Test |
||||
Personnel Protection Test |
KI-Discus containment and microbiological testing is performed |
|||
Product Protection Test 1~8×106 (three times in succession) |
≤5CFU |
|||
Cross-contamination Test 1~8×106 (three times in succession) |
≤2CFU |
|||
Sound Emission (Typical) |
||||
NSF/ANSI 49 |
<60dBA |
<60dBA |
<60dBA |
<65dBA |
EN 12469 |
<57dBA |
<59dBA |
<60dBA |
<62dBA |
Fluorescent Light Intensity |
800~1200 Lux (74~112 foot candles) |
|||
Excellent light distribution |
Yes |
|||
RMS |
≤2.3μm |
|||
Cabinet Construction |
||||
Main Body |
1.2mm(0.05”) steel with white oven-baked epoxy-polyester |
|||
Work Zone |
1.5mm(0.06”) stainless steel, type 304 |
|||
Side Walls |
1.5mm(0.06”) stainless steel, type 304 |
|||
Electrical sliding windows Option |
Yes |
|||
Window material |
Hardened/laminated safey glass |
|||
Electrical |
||||
Cabinet Full Load Amp(FLA) |
2A |
2A |
4A |
4A |
Fuses |
10A |
10A |
10A |
10A |
Cabinet Nominal Power |
361W |
452W |
813W |
850W |
Optional Outlets FLA |
5A |
5A |
5A |
5A |
Total Cabinet FLA |
7A |
7A |
9A |
9A |
Power Supply* |
||||
220V/50Hz |
Yes |
Yes |
Yes |
Yes |
220V/60Hz |
Yes |
Yes |
Yes |
Yes |
110V/60Hz |
Yes |
Yes |
N/A |
N/A |
Net Weight |
||||
Manual Type |
120kg(264lbs) |
225kg(496lbs) |
280kg(617lbs) |
320kg(705lbs) |
Shipping Weight |
||||
Manual Type |
175kg(386lbs) |
295kg(650lbs) |
350kg(772lbs) |
390kg(860lbs) |
Shipping Dimensions Maximum(W×D×H) |
1125×945×1717mm |
1425×945×1717mm |
1725×945×1717mm |
2026×945×1717mm |
46.3”×37.2”×67.3” |
56.1”×37.2”×67.3” |
67.9”×37.2”×67.3” |
79.8”×37.2”×67.3” |
|
Shipping Volume, Maximum |
1.81m³(63.9cu.ft.) |
2.30m³(81.2cu.ft.) |
2.79m³(98.5cu.ft.) |
3.27m³(115.5cu.ft.) |
General Specifications, HFsafe LCB2 Biological Safety Cabinets (Class II Type B2) |
||||
Model |
HFsafe-900LC |
HFsafe-1200LC |
HFsafe-1500LC |
HFsafe-1800LC |
Nominal Size |
0.9 meters(3′) |
1.2 meters(4′) |
1.5 meters(5′) |
1.8 meters(6′) |
External Dimensions with Base Stand (W×D×H) |
1040×790×2200mm 40.9”×31.1”×86.6” |
1340×790×2200mm 52.8”×31.1”×86.6” |
1640×790×2200mm 64.6”×31.1”×86.6” |
1940×790×2200mm 76.4”×31.1”×86.6” |
Internal Work Area, Dimensions(W×D×H) |
950×575×625mm 37.4”×22.6”×24.6” |
1250×575×625mm 49.2”×22.6”×24.6” |
1550×575×625mm 61.0”×22.6”×24.6” |
1850×575×625mm 72.8”×22.6”×24.6” |
Internal Work Area,Space |
0.54m2 (5.8 sq.ft) |
0.72m2 (7.8 sq.ft) |
0.9m2 (9.7 sq.ft) |
1.06m2 (11.6 sq.ft) |
Average Airflow Velocity * |
||||
Inflow |
0.53m/s(104.3fpm) |
|||
Downflow |
0.30m/s(59.1fpm) |
|||
Airflow Volume |
||||
Inflow |
363m³/h(214cfm) |
477m³/h(281cfm) |
592m³/h(348cfm) |
706m³/h(416cfm) |
Exhaust |
927m³/h(546cfm) |
1220m³/h(718cfm) |
1515m³/h(892cfm) |
1805m³/h(1062cfm) |
Filter Typical Efficiency |
||||
Downflow |
ULPA filters provide 99.9995% typical efficiency for particle size of 0.1 to 0.2 microns |
|||
Exhaust |
HEPA filters provide 99.97% typical efficiency for particle size of 0.3 microns |
|||
Biosafety Protection Test |
||||
Personnel Protection Test |
KI-Discus containment and microbiological testing is performed |
|||
Product Protection Test 1~8×106 (three times in succession) |
≤5CFU |
|||
Cross-contamination Test 1~8×106 (three times in succession) |
≤2CFU |
|||
Sound Emission (Typical) |
800~1200 Lux (74~112 foot candles) |
|||
NSF/ANSI 49 |
<60dBA |
<62dBA |
<62dBA |
<65dBA |
EN 12469 |
<57dBA |
<59dBA |
<60dBA |
<62dBA |
Fluorescent Light Intensity |
||||
Excellent light distribution |
Yes |
|||
RMS |
≤3μm |
|||
Cabinet Construction |
||||
Main Body |
1.2mm(0.05”) steel with white oven-baked epoxy-polyester |
|||
Work Zone |
1.5mm(0.06”) stainless steel, type 304 |
|||
Side Walls |
1.5mm(0.06”) stainless steel, type 304 |
|||
Electrical sliding windows Option |
Yes |
|||
Window material |
Hardened/laminated safey glass |
|||
Electrical |
||||
Cabinet Full Load Amp(FLA) |
4A |
4A |
5A |
5A |
Fuses |
10A |
10A |
10A |
10A |
Cabinet Nominal Power |
850W |
855W |
1200W |
1200W |
Optional Outlets FLA |
5A |
5A |
5A |
5A |
Total Cabinet FLA |
9A |
9A |
10A |
10A |
Power Supply* |
||||
220V/50Hz |
Yes |
Yes |
Yes |
Yes |
220V/60Hz |
Yes |
Yes |
Yes |
Yes |
Net Weight |
||||
Manual Type |
210kg(463lbs) |
250kg(551lbs) |
295kg(650lbs) |
340kg(750lbs) |
Shipping Weight |
||||
Manual Type |
260kg(573lbs) |
310kg(683lbs) |
365kg(804lbs) |
420kg(926lbs) |
Shipping Dimensions Maximum(W×D×H) |
1125×945×1710mm |
1425×945×1710mm |
1725×945×1710mm |
2026×945×1710mm |
44.3”×37.2”×67.3” |
56.1”×37.2”×67.3” |
67.9”×37.2”×67.3” |
79.8”×37.2”×67.3” |
|
Shipping Volume, Maximum |
1.81m³(64cu.ft.) |
2.30m³(81cu.ft.) |
2.79m³(99cu.ft.) |
3.27m³(115cu.ft.) |
According to your actual needs, choose the most reasonable overall design and planning procedures