Enteral feeding pump (W/O heating system) |
|||
Main features |
Oversize LCD for easy operationAutoperfusion improves work efficiency
More humanization design |
||
Safety |
Delivery deviation less than 10%
Various alarm functions |
||
Characteristic |
|||
Infusion rate range | 0-400ml/h(increment 1ml/h), with error less than ±10% | Temperature | +10℃~+30℃ |
Task setting range | 0-3000ml (increment 1ml) | Relative humidity | 30%~75% |
Dosing range | 0-3000ml (increment 1ml) | Air pressure | 700hpa~1060hpa |
Interval setting range | 1h-24h (increment 1h) | Language | English/Chinese |
Total infusion volume | 0-9999ml (minimum 1ml displayable) | Power supply | 100V-240V, 50/60HZ |
Clock |
Built-in 24h time clocking |
Memory function | 24h |
Alarm volume |
Low, middle and high |
Battery cruisingcapacity | Non-stop 24h under the pump operating at an infusion rate of 25ml/h |
Screen | LCD | Economic mode | Screen off mode |
Battery |
4 chargeable lithium cells, DC8.4V |
Service life | 5 years |
1.Choose continuous or intermittent infusion mode, the infusion mode for patients with different gastrointestinal functions which will help patients to carry out nutrition feeding as soon as possible
2.Screen off function during operation, night operation does not affect patient’s rest; the running light and alarm light indicate the pump running status when the screen is off
3.Add engineering mode, carry out speed correction, key test, check running log, alarm
Code
4.The maintenance interface realizes program update
Enteral feeding pump
Enteral feeding pump
1.Comply with electromagnetic compatibility standards and medical electrical appliances safety standards, and enhance the ability to resist electromagnetic interference
2.The internal layout of the main engine is rearranged, the pump door is added, and the overall sealing performance of the main engine is strengthened to prevent the nutrient solution from accidentally entering the main pump
3.The integrated design of the power supply seat and the connector on the main unit are dedicated, and cannot be interchanged with other brands to ensure that the main unit uses a power supply that meets the medical electrical safety standards
4.Equipped with a waterproof sound outlet to increase the volume of the speaker, and notify the medical staff of the feeding pump alarm in time
5.All alarm sounds are continuous. After the alarm, the alarm will stop only after human intervention, such as “task completed, pause timeout” alarm
6.With “pre-perfusion completed, power cord off” alarm, suitable for hospital use.
1.A liquid outlet is added under the heater compartment to prevent nutrient solution from being stored in the heater compartment and is easy to clean
2.The key structure design has passed 10,000 life inspections (internal testing by the company)
3.The solid infusion clamp structure can be repeatedly disassembled and assembled, and it is portable
4.With the prompt function: “Do not heat under the battery, recalculate the task, please set the parameters”, use it at a glance
5.With the function of clearing parameters, simplify the setting process
According to your actual needs, choose the most reasonable overall design and planning procedures